Description
Specifications Of Air-Conditioner Training System Model:
Body Material:
• Air-conditioner training system model is Steel Frame Structure
• Digital Thermal Printed Sheet
• Acrylic Round support board or Plastic Sheet
Working area:
• Working area: 32*25*6 Inch • Frame size: 40*30*6 Inch Safety Circuit Breaker • Operating voltage: 440V. • Cutting power (Icn): 10000A (10kA) (Ics-75% icn). • Characteristic curve: C. • Mechanical life: 20000 operations. • Electrical life: 10000 operations. • Earth-Leakage Protection. • Auto Short-Circuit Management • ERR Tripping sense Current 20m
Compressor:
• Power: 1/2HP,
• Single-phase 220V
• Control Box
AC Panel Meter:
• Measurement accuracy: 1%
• Measuring range: AC voltage: AC80-300V, AC
current: 0.1-100A
• Power consumption: 0.2VA
• Measuring speed: about 2 times per second
• Overall dimensions: 70 * 40 * 39mm
• Installation size: 68 * 38mm (embedded installation)
• The instrument is only suitable for pure AC 50-60HZ
of the mains power
Connector:
• Female Connector Diameter 13mm
• Male Connector Diameter 4.5mm
Input Power: 200/230V AC–1Ø–60 Hz Options
Basic Feature Of SPLIT TYPE AIR-CONDITIONER TRAINING SYSTEM MODEL :
* All system components* Including condenser
* Compressor, evaporator
* Capillary tube
* Filter, refrigerant receiver
* Accumulator
* Hand valves
* Pressure gauges
* Expansion devices
• Use control panel to select heat pump cycle (cooling
or heating), fan speed of evaporator and condenser,
and expanding path of the refrigerant
• Use control box to monitor the system voltage and
current as well as heat pump status.
• Three types of expansion devices
* Including capillary tube
* Pressure expansion valve
* Thermal expansion valve for refrigerant to pass
through.
6 sight glasses to observe the refrigerant status
before and after passing evaporator, condenser,
expansion devices, and compressor.
• 5 hand valves to control the flowing direction of the
refrigerant.
• High-and low-pressure protection switches to
automatically halt the compressor when detecting
wrong refrigerant flowing path.
• The refrigerant path for high pressure tube is painted
in red and low-pressure tube in blue.
Geothermal Heat Pump Components (water-tow
ater) –
• Microprocessor Control
• TXV Valve
• E-coated Air Coils
• Compressor-Rotary Type.
• Two-stage 24V Heating/Cooling Thermostat
• Mobile A Frame
• Instruction Manual and Text Book
• The following components shall be mounted on
mobile a frame-
• Electric Pressure Control (1 high and 1 low)• Filter Drier
• Sight Glass
• Condensers (2)
• 24V Two-Stage Heating/Cooling Thermostat
• Power Cord
• Water Supply Tank with Pump
• Water Storage Tank with Pump
• Programmable Thermostat
• Main AC Breaker with Pilot Light
• Pump Switch with Pilot Light (2)
• Digital Temperature Meter with Selector Switch
• Flow meter 0.5 – 5 GPM (2)
• High Pressure Refrigerant Gauge
• Low Compound Refrigerant Gauge
• Reversing Valve with Coil
• Suction Accumulator
• Section of Radiant Flooring with 3 Flooring Inserts
• Thermostatic Expansion Valves (2)
• H-RST-20-EFP Electrical Fault Package Option
• H-RST-20-MP Meter Package Option
Accessories Of SPLIT TYPE AIR-CONDITIONER TRAINING SYSTEM MODEL :
Experimental Manual : 1copy
Connecting Cord : 1 Set.
And other related Standard accessories.
Others:
Brand : Labinnova
Country Of Origin: China
Manufacturing : Assemble In Bangladesh
Training 5 Days
Warranty: One Year.
Reviews